98 99
Battery symbol
+ F10
battery voltage too
low
replace batteries of
radiator thermostat
Battery symbol
+ C symbol
battery voltage or one
or more taught-in de-
vices too low
replace batteries of
taught-in device
Antenna sym-
bolashing
connection to one or
more taught-in de-
vices is lost
/
nAC Teach-in procedure
failed
Restart teach-in
mode
Lock symbol local operating lock
active
deactivate opera-
ting lock
Lock symbol
+ C
global operating lock
active
deactivate operating
lock via CCU
Lock symbol
+ rES
local reset deacti-
vated
activate local reset
via CCU
Err Duty cycle exceeded the device will com-
municate again after
one hour, no action
required
Syn Attempts to synchro-
nize with know HM
device
/
CRC CRCerrorafterrm-
ware update
Repeatrmware
update
FUP Thermwareupdate
is in progress
/
tSd Temperature sensor
value defect or out
of range
replace device or
operate device in
current temperature
range
trd transceiver module
defect
replace device
21 Connectable components
The following HomeMatic components can be taught-
in to the Radiator Thermostat:
• max. 1 HomeMatic Central Control Unit
• max. 7 HomeMatic Radiator Thermostats
• max. 8 HomeMatic Door/Window Contact / Window
Rotary Handle Sensors
• max. 8 button pairs of HomeMatic Remote Controls
or Display Push-Buttons
• max. 1 HomeMatic Temperature Sensors
22 Scope of supply
Radiator thermostat
Adapters Danfoss RA / RAV / RAVL
Plunger extension Danfoss RAV
Cylinder head screw M4 x 12, nut M4
Support ring
2x 1.5 LR6/Mignon/AA